Home » Products » Coating Inspection » Coating Thickness Gauges » Dry Film Coating Thickness Gauge – Digital » Elcometer 355 Modular Coating Thickness Gauges
Elcometer 355 Modular Coating Thickness Gauges
Product Description
The Elcometer 355 Coating Thickness Gauge’s watchwords are accuracy, simplicity, versatility and durability making this a true state of the art hand-held measuring system packed with time-saving and cost-cutting features. Available as a standard and top model, the unit’s large memory stores up to 10,000 readings in batches, and data can be output to PC, data-logger or printer as required. With a comprehensive range of Probe Modules available, simply select the most appropriate for the application. All modules are supplied with calibration foils.
Each gauge is supplied without a probe allowing the choice of the correct probe for the relevant applications The Elcometer 355 Modular Coating Thickness Gauges can be used in accordance with:
The Standards not in bold have been superseded but are still recognised in some industries |
Specifications
Elcometer 355 Modular Coating Thickness Gauges – Specifications
Part Number | Description |
A355—-S | Elcometer 355 Standard Coating Thickness Gauge |
A355—-T | Elcometer 355 Top Coating Thickness Gauge |
Operating Temperature | 0°C to 50°C |
Storage Temperature | -10°C to 60°C |
Dimensions | 175 x 83 x 42mm |
Weight | 650g |
Reading Speed | 40 readings per minute |
Data Output | RS232C Serial or Parallel Output via D25 Type Connector (Female) |
Memory | Standard: 5,000 reading memory in pre-set batches |
Top: 10,000 reading memory in up to 200 batches (individually calibrated) | |
Battery Type | 3 x 1.5V AA Cells (Alkaline) or 3 x 1.5V Nickel Metal Hydride rechargeable cells |
Battery Life | Minimum: 40 hours with alkaline batteries, 20 hours with rechargeable batteries |
Certificate available | Certificate of Test – for variable calibration equipment and supplied with readings. |
A Certificate of Inspection states the instrument is tested in accordance with our procedures |
Packing List
- Elcometer 355 Top or Standard Gauge
- Leather carry case
- 3 x AA batteries
- ElcoMaster® software
- PC cable
- Operating instructions
Data Sheet
Elcometer 355 Modular Coating Thickness Gauges – Data Sheet
Elcometer 355 Modular Coating Thickness Gauges Data Sheet
Elcometer 355 Modular Coating Thickness Gauges Probe Options Data Sheet
Standards
Elcometer 355 Modular Coating Thickness Gauges – Standards
The Elcometer 355 Modular Coating Thickness Gauges can be used in accordance with:
- IMO MSC.215(82)
- IMO MSC.244 (83)
- ISO 1461
- ISO 19840
- ISO 2063
- ISO 2360
- ISO 2808-6A
- ISO 2808-6B
- ISO 2808-7C
- ISO 2808-7D
- ISO 2808-12
- ISO 2808-12
- AS 2331.1.4
- AS 3894.3-B
- AS/NZS 1580.108.1
- ASTM B 244
- ASTM B 499
- ASTM D 1186-B
- ASTM D 1400,
- ASTM D 7091
- ASTM E 376
- ASTM G 12
- BS 3900-C5-6A
- BS 3900-C5-6B
- BS 5411-3
- BS 5411-11
- BS 5599,
- DIN 50981
- DIN 50984
- ECCA T1
- EN 13523-1
- NF A49-211
- NF T30-124
- SS 184159
- SSPC PA 2
- US Navy PPI 63101-000
- US Navy NSI 009-32
The Standards not in bold have been superseded but are still recognised in some industries
Accessories
Elcometer 355 Modular Coating Thickness Gauges – Accessories
Elcometer 355 Probe Accessories | ||
Jumbo Hand Grip | ||
Ideal for precision placement for the most accurate results on flat and curved surfaces. Place the probe inside the Jumbo Hand Grip and take measurements – ideal when wearing gloves. | ||
T9997766- | Jumbo Hand Grip – F and N Probes | |
Use with the following Elcometer 355 probes: | ||
F1 Standard, F2 Standard, F4 Standard, F5 Rebar, N1 Standard | ||
V-Probe Adaptor | ||
Ideal for precision placement for the most accurate results on medium and large diameter curved surfaces such as pipes and cylinders. | ||
T9997381 | V-Probe Adaptor – F and N Probes | |
Use with the following Elcometer 355 probes: | ||
F1 Standard, F2 Standard, F4 Standard, F5 Rebar, N1 Standard | ||
Soft Material / Blanket Probe | ||
Ideal for taking precision readings on soft coatings or printing blankets. The wide, flat base design acts as a load spreader, reducing the total force at a single point. | ||
T35511963 | Soft Material / Blanket Probe for the Elcometer 355 | |
Probe Placement Jig | ||
For the most reliable and repeatable coating thickness measurements, making the gauge score highly in repeatability and reproducibility studies. Ideal for small and large components alike. The probe placement jig is supplied with a probe housing to suit standard F1, F2, F4, F5 and N1 probes. Housings to suit other probes are available as optional accessories. | ||
T95012880 | Probe Placement Jig | |
T95013028 | Component Hand Vice – a simple vice to hold small components | |
T95012888 | Cable Release Assembly – ideal for remote measurements | |
T95015589 | N4 Probe Adaptor – must be purchased for use with N4 Probes | |
Use with the following probes: | ||
F1 Standard, F2 Standard, F4 Standard, F5 Rebar, N1 Standard and N4 Standard |
Probe Options
Elcometer 355 Modular Coating Thickness Gauge Probe Options
Elcometer 355 Ferrous and Non-Ferrous Probes
Unique probe modules allow the Elcometer 355 Standard Coating Thickness Gauges to be versatile and flexible for any measurement application.
Probe modules can be freely interchanged as required for both ferrous (F) and non-ferrous (N) metal substrates.
Most probe modules are capable of an accuracy of ±1% of the reading on a variety of coatings and surfaces.
Telescopic probes extend from 410mm to 1100mm.
Scale 1 | Range: | 0-1500μm | Accuracy*: ±1% or ±1μm | |
Resolution: | 0.1μm: 0-200μm; 0.5μm: 200-500μm; 1μm: 500-1500µm | |||
Standard | Right Angle | Telescopic | N1 Standard | |
Probe Design | Part Number | Minimum Headroom | Minimum Sample Diameter | Certificate |
F1 Standard | T35511952 | 85mm | 6mm | • |
F1 Telescopic | T35511959 | 30mm | 6mm | • |
N1 Standard | T35511982 | 85mm | 8mm | • |
Scale 2 | Range: | 0-5mm | Accuracy*: ±1% or ±5μm | |
Resolution: | 2μm: 0-500μm; 5μm: 500-5000μm | |||
F2 Standard | F2 Telescopic | N2 Standard | ||
Probe Design | Part Number | Minimum Headroom | Minimum Sample Diameter | Certificate |
F2 Telescopic | T35511960 | 36mm | 10mm | • |
N2 Standard | T35511984 | 88mm | 18mm | • |
Scale 4 | Range: | 0-250µm | Accuracy*: ±1% or ±1μm | |
Resolution: | 0.1µm: 0-250µm | |||
F4 Standard | F4 Right Angle (long) | N4 Standard | ||
Probe Design | Part Number | Minimum Headroom | Minimum Sample Diameter | Certificate |
F4 Standard | T35511950 | 85mm | 4mm | • |
F4 Right Angle (long) | T35511951 | 18mm | 3mm | • |
N4 Standard | T35511980 | 90mm | 8mm | • |
Scale 5 | Range: | 0-250µm | Accuracy*: ±1% or ±1μm | |
F5 Rebar | ||||
Probe Design | Part Number | Minimum Headroom | Minimum Sample Diameter | Certificate |