Dakota FX80 Benchtop Flaw Detector (DFX-8)

Product Description

Designed for use in the laboratory, these gauges are the tool you need for all your flaw detecting needs.

The Dakota FX80 Bench Top Ultrasonic Flaw Detector is available in two models: Dakota FX80-DL Bench Top Flaw Detector and Dakota FX81-DL Bench Top Flaw Detector.

The time corrected gain (TCG) feature automatically compensates for sound attenuation through a material, further increasing the performance of the gauge.

Within the grid batching of the Dakota FX80 Flaw Detector the user has the capability to enter ‘OBSTRUCT’ on to the grid for easy identification of inaccessible locations to measure.

The Dakota FX80 Ultrasonic Flaw Detector has a 6Gb internal memory and an external SD slot which allows up to 64Gb with full data logging via RS232 data output to DakMaster™ data management software.

Key Features

Features:

  • Blanview sunlight readable QVGA TFT colour display
  • Sizing Toolkits: DAC, AWS, TCG, DGS
  • Pulse Repetition Frequency: 8 to 333 Hz, adjustable
  • Screen Refresh Rate: 60Hz
  • Detection: Z-Cross, Flank & Peak
  • Automatic: probe zero, probe recognition, and temperature compensation
  • Measurement: Variety of modes to address a number of applications
  • Large data storage: 6Gb internal & up to 64Gb external SD slot
  • Multiple formats: Alpha numeric grid and sequential with auto identifier
  • Up to 12 hours of battery life
  • Download to DakMaster™ data management software

Product Features

ModelFX80-DL & FX81-DL
Display Mode 
Material thickness digits display 
B-Scan cross sectional display 
B-Scan with digits display 
Scan bar display 
Coating thickness display 
A-Scan display+ Rectified, – Rectified, Full Waveform (RF)
Flaw Detection ModesTRIG, DAC, AWS, TCG, AVG/DGS
Measurement RangeP-E:
Pulse Echo (Dual Contact) : 0.630 – 2,440mm
Pulse Echo (Single Contact) : 1.000 – 30,480mm
E-E:
Echo Echo ThruPaint™ (Dual Contact): 1.270 – 102mm
Echo Echo (single delay line) : 0.178 – 25.4mm
Echo Echo (single contact) : 1.000 – 3,050mm
Echo Echo Verify (EEV): 1.270 – 25.4mm
PETP:
Pulse Echo Temp Comp: 0.630 – 2,440mm
CT:
Coating Thickness: 0.013 – 2.54mm
PECT:
Pulse Echo Coating Thickness (Coating) 0.010 – 2.54mm
Pulse Echo Coating Thickness (Substr.) 0.630 – 2,440mm
Resolution0.01mm , 0.001mm selectable
Measurement Rate (Thickness Mode) 
Manual4 readings per second
Scan Mode32 readings per second
Scan bar display6 readings per second
High Speed Scan Mode 
Differential Mode 
Limit alarm mode 
B-Scan display speedadjustable display speed
Calibration setups64 user-definable setups transferrable to and from a PC archive
Gates2 (flaw) and 3 (thickness) adjustable gates: start, stop, width & threshold
Damping50, 75, 100, 300, 600, & 1500 ohms
Pulser typeFX80-DL: Two adjustable square wave pulsers, 100 – 200v
FX81-DL:Two tone burst pulsers, 100 – 400v
GainManual, automatic gain control (AGC) with 110dB range with 0.2dB resolution
TimingPrecision TCXO timing with single shot 100 MHz 8 bit ultra-low power digitizer
Memory and Data Logging4GB internal memory
Sequential and grid logging
Alpha numeric batch identification
OBSTRUCT indicates inaccessible locations
Bitmap graphic capture
Data OutputUSB-C
Calibration Optionssingle, two point, velocity, material type
Transducer recognitionAutomatic
V-path / dual path error correctionAutomatic
Probe ZeroAutomatic
Automatic CalibrationLongitudinal (straight), or Shear (angle)
Flaw Detection Product Features
Probe TypesSingle Contact, Dual, Delay & Angle
Material Velocity TableContains longitudinal and shear velocities for a variety of material types
TRIGTrigonometric display of beam path, depth, surface distance, and curved surface correction. Used with angle beam transducers
DACUp to 8 points may be entered and used to digitally draw a DAC curve. Reference -2, -6, -10, (-6/-12), (-6/-14), (-2/-6/-10) dB. Amplitude displayed in %DAC, dB, or %FSH
AWSAutomatic defect sizing in accordance with AWS D1.1 structural welding code.
AVG/DGSAutomatic defect sizing using probe data. Stores up to 64 custom setups
TCGTime corrected gain. 50 dB dynamic range, 20 dB per microsecond, up to 8 points for curve definition
Detection ModesZero Crossing, Flank and Peak
Display FreezeHold current waveform on screen
Peak MemoryCaptures peak signal amplitude
PRF8 to 2000Hz in selectable steps (8, 16, 32, 66, 125, 250, 333, 1000, 2000Hz)
Skip BarDisplays skip legs in the waveform area
Pulse Width40 to 400 ns. Selectable step options 40, 80 & 400 ns (labeled spike, thin & wide)
Frequency BandsFX80-DL & FX81-DL: Broadband 1.8 – 19MHz (-3dB)
FX81-DL: Six narrow bands at 0.5MHz, 1MHz, 2MHz, 5MHz, 10MHz, 15MHz.
Horizontal Linearity+/- 0.4% FSW
Vertical Linearity+/- 1% FSH
Amplifier Linearity+/- 1 dB
Amplitude Measurement0 to 100% FSH, with 1% resolution
Delay0 – 999in (25,375mm) at steel velocity
DisplayBlanview sunlight readable QVGA TFT colour display. 115.2 x 86.4mm viewable screen
Display Refresh Rate60Hz
Units (selectable)mm
BacklightAdjustable brightness
Repeatability / Stability Indicator 
Low Battery Indicator 
Battery Save ModeAuto

Technical Specifications

Part NumberDescriptionCertificate
Z-250-0001Dakota FX80-DL Benchtop Flaw Detector (DFX-8)
Z-251-0001Dakota FX81-DL Benchtop Flaw Detector (DFX-8+)
Operating Temperature-10 to 60ºC 
Power Supply6 x AA batteries and via USB
Battery Life2Alkaline (12hrs), Nicad (5hrs), and NI-MH (12hrs)
Gauge Weight2.04kg – including batteries
Gauge Dimensions216.0 x 165.0 x 70.0mm

● Certificate of Calibration supplied as standard

Data Sheet

Standards


Thickness Gauge: Factory calibration traceable to NIST & MIL-STD-45662A.

Flaw Detector: EN12668-1 compliant.

Part Numbers

Dakota FX80-DL Benchtop Flaw Detector (DFX-8)  
Part Number:Z-250-0001
  
  
  
  
  
Dakota FX81-DL Benchtop Flaw Detector (DFX-8+)  
Part Number:Z-251-0001
  
  
  
  
  

Packing List

Packing ListZ-250-0001Z-251-0001
Unit
Selectable Transducer
Couplant
Manual
Power Cable
Plastic Carrying case
Certificate of Calibration
AA Batteries
PC Software
Data Transfer Cable