Dakota FX70 Flaw Detector (DFX-7)

Product Description

The Dakota FX70 Flaw Detector is available in two models: Dakota FX70-DL Flaw Detector and Dakota FX71-DL Flaw Detector.

Whether you are on-site or in the laboratory these gauges are the tool you need for all your flaw detecting needs.

The time corrected gain (TCG) feature automatically compensates for sound attenuation through a material, further increasing the performance of the gauge.

The Dakota FX70 Ultrasonic Flaw Detector stores up to 4GB worth of readings with A/B-scan images in alpha numeric batches with full data logging and firmware updates via USB data output to DakMaster data management software.

Features:

  • Exceptional visibility in sunlight (AMOLED)
  • colour VGA display (320×240 pixels)
  • Sizing Toolkits: DAC, AWS, TCG, DGS
  • Pulse Repetition Frequency: 8 to 2000Hz, adjustable
  • Detection: Z-Cross, Flank & Peak
  • Automatic: probe zero, probe recognition, and temperature compensation
  • Measurement: Variety of modes to address a number of applications
  • Large data storage with multiple formats: Alpha numeric grid and sequential with auto identifier
  • Download to DakMaster data management software
  •  

  • Summary

    Versatile
    The Dakota FX70 Flaw Detector series has two functions, a thickness gauge and a flaw detector. When the Dakota FX70 Flaw Detector is set to thickness gauge it has the ability to measure coatings and material thickness simultaneously. When set to flaw detector the gauge has the ability to detect the size and position of flaws and to differentiate between flaw types in various materials and welded joints.
    Intelligent
    User definable limits for pass/fail indication. Set hi/lo limits for pass/fail indication with audible warnings and built-in differential mode for quality control inspections.
    Powerful
    Store each measurement for further analysis. Up to 4GB of readings can be saved into the gauge memory as each measurement is taken, which can be downloaded later into an inspection application or into DakMaster Software for further analysis and reporting.
    Customisable
    Customisable tool kits and reading display. The Dakota FX70 Ultrasonic Flaw Detector has a choice of display modes allowing the user to select the most appropriate for their needs; from A & B-Scan displays to flaw detection modes such as TRIG, DAC, TCG, Flank and Peak.

    Detection Methods

    Zero Crossing: Flank:
    The gate detects the flank of the pulse, but the measurement is taken at the next crossing of the x axis. This is the most common type of detect in ultrasonic measurement.The gate is triggered by the flank (or side) of the pulse on the graph and the measurement taken at this exact point.
    Peak:TRIG:
    The gate is triggered by the intersection with the A-scan pulse and the detection is taken from the next peak in the signal (when it stops rising and starts falling).
     

    TRIG enabling location of flaws in both surface distance and depth. Trigonometric display of beam path, depth, surface distance, and curved surface correction. Used with angle beam transducers.

    DAC:AWS:
    Distance amplitude correction for the creation of DAC curves which are used to inform the operator of the size of any given flaw at any depth.The American Weld Standard function provides automatic defect sizing in accordance with AWS D1.1 structural welding code.
    TCG: 
    Time corrected gain increases gain as distance increases, in order to achieve an over all level of sensitivity for the same flaw/reflector at different distances. 

Product Features

Material Thickness Features
ModelFX70-DL & FX71-DL
Display Mode 
Material thickness digits display
B-Scan cross-sectional display
B-Scan with digits display
Scan bar display
Coating thickness display
A-Scan display+ Rectified, – Rectified, Full Waveform (RF)
Flaw Detection ModesTRIG, DAC, AWS, TCG, AVG/DGS
Measurement RangePulse Echo (PE) 0.63 – 2,440mm
Pulse Echo (single contact) 1.0 – 30,480mm
Echo Echo ThruPaint (EE) 1.27 – 102mm
Echo Echo (single delay line) 0.178 – 25.4mm
Echo Echo (single contact) 1.0 – 3,050mm
Echo Echo Verify (EEV) 1.27 – 25.4mm
Pulse Echo Temp Comp (PETP) 0.63 – 2,440mm
Coating Thickness (CT) 0.0127 – 2.54mm
Pulse Echo Coating Thickness (PECT) 0.01 – 2.54mm
Pulse Echo Coating Thickness (PECT) 0.63 – 2.440mm
Resolution0.01mm , 0.001mm selectable
Measurement Rate (Thickness Mode) 
Manual8 Readings per second
Scan Mode50 Readings per second
Scan bar display10 Readings per second
High Speed Scan Mode
Differential Mode
Limit alarm mode
B-Scan display speedAdjustable display speed
Calibration setups64 User-definable setups transferrable to and from a PC archive
Gates2 (flaw) and 3 (thickness) adjustable gates: start, stop, width & threshold
Damping50, 75, 100, 300, 600, & 1500 ohms
Pulser typeTwo adjustable square wave pulsers and receivers
GainManual, automatic gain control (AGC) with 110dB range with 0.2dB resolution
TimingPrecision TCXO timing with single shot 100 MHz 8 bit ultra-low power digitizer
Memory and Data Logging• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
Data OutputUSB-C
Calibration OptionsSingle, two point, velocity, material type
Transducer recognitionAutomatic
V-path / dual path error correctionAutomatic
Probe ZeroAutomatic
Automatic CalibrationLongitudinal (straight), or Shear (angle)
Flaw Detection Product Features
Probe TypesSingle Contact, Dual, Delay & Angle
Material Velocity TableContains longitudinal and shear velocities for a variety of material types
TRIGTrigonometric display of beam path, depth, surface distance, and curved surface correction. Used with angle beam transducers
DACUp to 8 points may be entered and used to digitally draw a DAC curve. Reference -2, -6, -10, (-6/-12), (-6/-14), (-2/-6/-10) dB. Amplitude displayed in %DAC, dB, or %FSH
AWSAutomatic defect sizing in accordance with AWS D1.1 structural welding code.
AVG/DGSAutomatic defect sizing using probe data. Stores up to 64 custom setups
TCGTime corrected gain. 50 dB dynamic range, 20 dB per microsecond, up to 8 points for curve definition
Detection ModesZero Crossing, Flank and Peak
Display FreezeHold current waveform on screen
Peak MemoryCaptures peak signal amplitude
PRF8 to 2000Hz in selectable steps (8, 16, 32, 66, 125, 250, 333, 1000, 2000Hz)
Skip BarDisplays skip legs in the waveform area
Pulse Width40 to 400 ns. Selectable step options 40, 80 & 400 ns (labeled spike, thin & wide)
Frequency BandsFX70-DL & FX71-DL: Broadband 1.8 – 19MHz
FX71-DL: Three narrow bands at 2MHz, 5MHz, 10MHz
Horizontal Linearity+/- 0.4% FSW
Vertical Linearity+/- 1% FSH
Amplifier Linearity+/- 1 dB
Amplitude Measurement0 to 100% FSH, with 1% resolution
Delay0 – 999in (25,375mm) at steel velocity
Display1/4 VGA AMOLED colour display 57.6 x 43.2mm  viewable area
Display Refresh Rate60Hz
Units (selectable)mm
BacklightAdjustable brightness
Repeatability / Stability Indicator
Low Battery Indicator
Battery Save ModeAuto

Technical Specifications

Part NumberDescription
Z-220-0005Dakota FX70-DL Flaw Detector (DFX-7)
Z-221-0005Dakota FX71-DL Flaw Detector (DFX-7+)
Operating Temperature-10 to 60ºC
Power Supply3 x AA batteries and via USB
Battery Life2Alkaline (12hrs), Nicad (5hrs), and NI-MH (12hrs)
Gauge Weight397g – including batteries
Gauge Dimensions63.5 x 165 x 31.5mm

Certificate of Calibration supplied as standard

Data Sheet

Standards

Thickness Gauge: Factory calibration traceable to NIST & MIL-STD-45662A.

Flaw Detector: EN12668-1 compliant.

Part Numbers

Dakota FX70-DL Flaw Detector (DFX-7)  
Part Number:Z-220-0005
  
  
  
  
  
Dakota FX71-DL Flaw Detector (DFX-7+)  
Part Number:Z-221-0005
  
  
  
  
  
  • Packing List


    Packing ListModel
     Z-220-0005Z-221-0005
    Unit
    Selectable Transducer
    Couplant
    Manual
    Plastic Carrying Case
    Certificate of Calibration
    AA Batteries
    PC Software
    Data Transfer Cable