Elcometer 6910 Setaflash Series 8 Active Cool Closed Cup Tester


Product Description

The Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester offers the same features as the Setaflash ‘Series 8’ Closed Cup Tester but is designed with a temperature range of -30°C to 135°C with no external cooling required.

This Active Cool Closed Cup Tester uses the Peltier cell technology for heating and cooling, ensuring precise temperature control and rapid cool down after a test is completed.

Features of the Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester

  • Small sample size, 2ml or 4ml
  • Flash/No Flash & Ramp Modes
  • Electric ignitor
  • Active-Cool electronic Peltier cooling
  • 1GB internal memory & integrated USB port


Elcometer 6910 Setaflash Series 8 Active Cool Closed Cup Tester can be used in accordance with:

  • ASTM D3278
  • ASTM D3828
  • ASTM D7236
  • ASTM E502
  • BS 2000-523
  • CLP Regulations EC No 1272/2008
  • EPA 1020 A & B
  • ISO 3679
  • ISO 3680*
  • UN Class 3 Non-viscous Flammable Liquids

* Standards not bolded have been superseded but are still recognised in some industries

Specifications

Elcometer 6910 Setaflash Series 8 Active Cool Closed Cup Tester – Specifications

Part Number Description Certificate 
K6910M021 Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
Temperature Range -30°C to 135°C
Sample Size 2ml or 4ml according to method
Test Mode Rapid Equilibrium and Ramp
Test Duration Rapid Equilibrium Mode 1 minute below 100°C
2 minutes above 100°C
Test Duration Ramp Mode Typically, 7 minutes
Cool Down Time 80°C to 20°C in 4 minutes
Cup Material Aluminium
Dimensions 300 x 340 x 380mm
Weight 8kg

• Calibration Certificate supplied as standard.
* Standards not in bold have been superseded but are still recognised in some industries

Data Sheet

Elcometer 6910 Setaflash Series 8 Active Cool Closed Cup Tester – Data Sheet

Elcometer 6910 Setaflash Series 8 Active Cool Closed Cup Tester Data Sheet

Standards

Elcometer 6910 Setaflash Series 8 Active Cool Closed Cup Tester – Standards

Elcometer 6910 Setaflash Series 8 Active Cool Closed Cup Tester can be used in accordance with:

  • ASTM D3278
  • ASTM D3828
  • ASTM D7236
  • ASTM E502
  • BS 2000-523
  • CLP Regulations EC No 1272/2008
  • EPA 1020 A & B
  • ISO 3679
  • ISO 3680*
  • UN Class 3 Non-viscous Flammable Liquids

* Standards not bolded have been superseded but are still recognised in some industries

Accessories

Elcometer 6910 Setaflash Series 8 Active Cool Closed Cup Tester – Accessories

Part Number Description
KT006910N009 Certified Flash Point Material