Elcometer 138 Basic Bresle Salt Kit - Discontinued


Elcometer 138 Basic Bresle Salt Kit

Product Description

If a coating is applied to a contaminated surface, which is not properly prepared, it could fail prematurely resulting in costly re-coating and high maintenance costs.

Therefore it is essential to measure the level of contaminants on a surface prior to coating application to ensure the quality of the coating and that its optimum lifetime is achieved.

The Elcometer 138 Basic Bresle Salt Kit includes the Elcometer 138E Conductivity Meter and Elcometer 135C Bresle Test Patches. This lightweight, portable conductivity meter accurately measures the salinity of the test samples.

The sensor cartridge can be easily replaced when necessary and displays conductivity in a range of units including: S/cm and S/m.

The Elcometer 138 Basic Bresle Salt Kit can be used in accordance with:

    • ISO 8502-6
    • ISO 8502-9
    • AS 3894.6-A
    • IMO MSC.215 (82)
    • IMO MSC.244 (83)
    • SSPC Guide 15
    • US Navy NSI 009-32
    • US Navy PPI 63101-000

Specifications

Elcometer 138 Basic Bresle Salt Kit – Specifications

Part Number Description
E138-EC Elcometer 138 Basic Bresle Salt Kit with Elcometer 135C Bresle Test Patches
Tests per Kit 25
Dimensions 300 x 220 x 75mm
Weight 2.1kg
Accuracy & Measuring Range 1% full scale ±1 digit / 0 μS/cm to 200.0 μS/cm, 0 μS/cm to 2000 μS/cm, 0 mS/cm to 20 mS/cm

 

Elcometer 138 Bresle Kit Packing list:

      • Box of 25 Elcometer 135C Bresle Test Patches, Elcometer 138E Conductivity Meter, 250ml (8.5fl oz) bottle of pure water, 3 x 3ml (0.1fl oz) syringes, 3 x blunt needles, 1 x 20ml (0.74 fl oz) Single Use Pouch Standard 1413 µS/cm (1.413 mS/cm) Calibration Solution, 30ml (1fl oz) plastic beaker, 4 x LR44 batteries, transit case & user guide

Data Sheet

Elcometer 138 Basic Bresle Salt Kit – Data Sheet

Elcometer 138 Basic Bresle Salt Kit Data Sheet

Standards

Elcometer 138 Basic Bresle Salt Kit – Standards

The Elcometer 138 Bresle Kit can be used in accordance with:

      • ISO 8502-6
      • ISO 8502-9
      • AS 3894.6-A
      • IMO MSC.215 (82)
      • IMO MSC.244 (83)
      • SSPC Guide 15
      • US Navy NSI 009-32
      • US Navy PPI 63101-000

Test Method

Elcometer 138 Basic Bresle Salt Kit Test Method

The surface density of soluble salts can be tested by using the Elcometer 135B Bresle Patch together with a conductivity meter, test strips which change colour or titration tubes. Outlined below is the procedure for testing the surface with the Elcometer 135B and a conductivity meter.

Please note that this is intended as a guide only. The relevant ISO standard should be referred to for precise instructions.

      1. Remove the protective paper and the square in the centre of the patch.
      2. Attach the Elcometer 135B Bresle Patch to a dry and clean test surface.
      3. Measure a given amount of distilled water into a measuring tube or beaker, clean the syringe using this water.
      4. Using a conductivity meter, measure the electrical conductivity of the distilled water in the measuring tube.
      5. Using the water in the measuring tube or beaker, inject a given amount into the Bresle Patch which is adhered to the test surface.
      6. Pump the water back and forth between the syringe and the patch, to dissolve the soluble salts on the test surface.
      7. Remove all the distilled water from the patch using the syringe and return it to the measuring tube or beaker.
      8. Re-measure the electrical conductivity of the water

Instruction Manual

Elcometer 138 Basic Bresle Salt Kit – Instruction Manual

Elcometer 138 Bresle Salt Kit Instruction Manual