Home » Products » Coating Inspection » Coating Thickness Gauges » Dry Film Coating Thickness Gauge – Digital » Elcometer 456 Coating Thickness Gauge / Digital Dry Film Thickness Gauges (DFTG)
Elcometer 456 Coating Thickness Gauge / Digital Dry Film Thickness Gauges (DFTG)
Product Description
The Elcometer 456 Coating Thickness Gauge sets new standards; providing reliable and accurate coating thickness measurements; helping you to become more efficient.
The Elcometer 456 Dry Film Thickness Gauge is available in three different models. Each coating thickness gauge provides the user with increasing functionality – from the entry level Elcometer 456 Basic, to the top of the range Elcometer 456 Top.
Integral dry film coating thickness gauges are ideal for single handed operation as the wide footprint of the Bigfoot™ internal probe provides greater stability during coating thickness measurement – allowing for consistent, repeatable and accurate dry film thickness results.
Separate dry film coating thickness gauge models, with their wide range of probes, provide even greater dry film thickness measurement flexibility.
Compatible with ElcoMaster® software and ElcoMaster® Mobile App, individual coating thickness measurements can be transferred via USB or Bluetooth to PC or a mobile device for analysis and instant report generation.
Features of the Elcometer 456 Dry Film Thickness Gauge
• Specialised probes to meet a wide range of applications
• Integral and separate gauges to measure coatings up to 30mm
• Dust and water resistant rugged design to IP65
• Drop tested to a height of 2m
• Secure probe connection for improved durability
• Bigfoot™ integral probe for accurate and repeatable measurements
• Ergonomic design for comfort during continuous use
• 2.4″ (6cm) colour screen provides enhanced reading visibility at all angles
• Fast reading rate of more than 70 readings per minute
• Large easy to read colour display
• Scratch and solvent resistant screen
• Alpha numeric batch identification
• Large positive buttons with feedback
• USB and to ElcoMaster® 2.0 software Bluetooth data output
Easy
Accurate
Reliable
Rugged
Efficient
Powerful
|
Product Features of the Elcometer 456 Coating Thickness Gauge
■ Standard | □ Optional | |||
Model B | Model S | Model T | ||
Fast, accurate reading rate; 70+ readings per minute | ■ | ■ | ■ | |
Repeatable & reproducible measurements | ■ | ■ | ■ | |
Easy to use menu structure; in 30+ languages | ■ | ■ | ■ | |
Tough, impact, water & dust resistant; equivalent to IP64 | ■ | ■ | ■ | |
Bright colour screen; with permanent back light | ■ | ■ | ■ | |
Scratch & solvent resistant display; 2.4″ (6cm) TFT | ■ | ■ | ■ | |
Large positive feedback buttons | ■ | ■ | ■ | |
USB power supply; via PC | ■ | ■ | ■ | |
Test certificate | ■ | ■ | ■ | |
2 year gauge warranty* | ■ | ■ | ■ | |
Automatic rotating display; 0°, 90°, 180° & 270° | ■ | ■ | ■ | |
Ambient light sensor; with adjustable auto brightness | ■ | ■ | ■ | |
Emergency light | ■ | ■ | ■ | |
Tap awake from sleep | ■ | ■ | ■ | |
Gauge software updates¹; via ElcoMaster® software | ■ | ■ | ■ | |
Data output | ■ | ■ | ■ | |
USB; to computer | ■ | ■ | ■ | |
Bluetooth®; to computer, Android™ & iOSǂ devices | ■ | ■ | ||
On screen statistics | ■ | ■ | ■ | |
Number of readings; η | ■ | ■ | ■ | |
Mean (average); x | ■ | ■ | ■ | |
Standard deviation; ó | ■ | ■ | ■ | |
Highest reading; Hi | ■ | ■ | ■ | |
Lowest reading; Lo | ■ | ■ | ■ | |
Coefficient of variation; CV% | ■ | ■ | ■ | |
Elcometer index value²; EIV | ■ | ■ | ■ | |
Nominal dry film thickness; NDFT | ■ | ■ | ||
IMO PSPC; %>NDFT, %>90 | ■ | ■ | ||
High & low limits; definable audible & visual alarms | ■ | ■ | ||
Number above high limit; | ■ | ■ | ||
Number below low limit; | ■ | ■ | ||
Live reading trend graph; in batch mode | ■ | ■ | ||
ElcoMaster® software & USB cable | □ | ■ | ■ | |
Replaceable screen protectors | □ | ■ | ■ | |
Protective case | ■ | ■ | ■ | |
Plastic transit case | □ | □ | ■ | |
Integral models; with automatic gauge switch on | ■ | ■ | ■ | |
Probe type; Ferrous (F), Non-Ferrous (N), Dual (FNF)³ | F, N, FNF | F, N, FNF | F, N, FNF | |
Measurement range | 0-13mm | 0-1500μm | 0-1500μm | |
Separate models; with automatic probe recognition | ■ | ■ | ■ | |
Probe type; Ferrous (F), Non-Ferrous (N), Dual (FNF)³ | F, N, FNF | F, N, FNF | F, N, FNF | |
Measurement range | 0-31mm | 0-31mm | 0-31mm | |
On-screen calibration instructions; in 30+ languages | ■ | ■ | ■ | |
Multiple calibration methods | ■ | ■ | ■ | |
Factory; resets to the factory calibration | ■ | ■ | ■ | |
2-point; for smooth and rough surfaces | ■ | ■ | ■ | |
1-point; zero calibration | ■ | ■ | ■ | |
Zero offset4; for calibration according to ISO19840 | ■ | ■ | ||
Predefined calibration & measurement methods | ■ | ■ | ||
ISO, SSPC PA2, Swedish, Australian | ■ | ■ | ||
Automatic calibration; for rapid calibration | ■ | ■ | ||
Calibration memory type; gauge (g) or gauge & batch (gb) | g | gb | gb | |
Number of batches; with unique calibrations | 1 | 2,500 | ||
Calibration memories; 3 user-programmable memories | ■ | |||
Measurement outside calibration warning | ■ | |||
Calibration lock with optional PIN code unlock | ■ | ■ | ■ | |
Delete last reading | ■ | ■ | ■ | |
Gauge memory; number of readings | Last 5 | 1,500 | 150,000 | |
Individual batch calibrations; sent to PC via ElcoMaster® | ■ | ■ | ■ | |
Limits user definable audible & visual pass/fail warnings | ■ | ■ | ■ | |
Gauge (g) or gauge & batch specific (gb) limits | g | gb | ||
Date and time stamp | ■ | ■ | ||
Batch types; normal, counted average, IMO PSPC | ■ | ■ | ||
Navsea Mode | ■ | |||
Batch review graph | ■ | |||
Review, clear & delete batches | ■ | ■ | ||
Copy batches and calibration settings | ■ | |||
Alpha-numeric batch names; user definable on the gauge | ■ | |||
Scan & Auto Repeat Modes; with Scan probe connected | ■ | |||
Fixed batch size mode; with batch linking | ■ |
* The Elcometer 456 is extendable within 60 days from date of purchase, free of charge, to 2 years
ǂ Visit www.elcometer.com/sdk to find out how to integrate Elcometer’s MFi certified products to your App
1 Internet connection required
2 Elcometer Index Values are used in the automotive industry to assess a coating’s overall quality; USA patent number US7606671B2
3 FNF patent number USA: 5886522
4 Zero Offset USA patent number US6243661
The Elcometer 456 Coating Thickness Gauge can be used in accordance with:
• AS 2331.1.4
• AS 3894.3-B
• AS/NZS 1580.108.1
• ASTM B 499
• ASTM D 1186-B*
• ASTM D 1400*
• ASTM D 7091
• ASTM E 376
• ASTM G 12
• BS 3900-C5-6B*
• BS 3900-C5-6A*
• BS 5411-11*
• BS 5411-3*
• BS 5599
• DIN 50981*
• DIN 50984*
• ECCA T1*
• EN 13523-1
• IMO MSC.215(82)
• IMO MSC.244 (83)
• ISO 1461
• ISO 19840
• ISO 2063
• ISO 2178
• ISO 2360
• ISO 2808-6A*
• ISO 2808-6B*
• ISO 2808-7C
• ISO 2808-7D
• ISO 2808-12
• JIS K 5600-1-7
• NF T30-124
• SS 184159*
• SSPC PA 2
• US Navy PPI 63101-000
• US Navy NSI 009-32
Specifications
Elcometer 456 Coating Thickness Gauge / Digital Dry Film Thickness Gauges (DFTG) – Specifications
Display information | 2.4″ (6cm) QVGA colour TFT display, 320 x 240 pixels |
Battery type | 2 x AA dry cell batteries, rechargeable batteries can also be used |
Battery life | ~24 hours of continuous use at 1 reading per second5 |
Gauge dimensions (h x w x d) | 141 x 73 x 37mm |
Gauge weight | 161g including supplied batteries |
Operating temperature | -10 to 50°C |
Gauges with Integral Probes
Scale 1 | |||||
Range: | 0-1500μm | ||||
Accuracy*: | ±1-3% or ±2.5μm | ||||
Resolution: | 0.1μm: 0-100μm; 1μm: 100-1500μm | ||||
Model B | Model S | Model T | C | ||
Elcometer 456 Ferrous Integral | A456CFBI1 | A456CFSI1 | A456CFTI1 | ● | |
Elcometer 456 Non-Ferrous Integral | A456CNBI1 | See separate gauges with N2 PINIP™ Probe | ● | ||
Elcometer 456 Dual FNF Integral | A456CFNFBI1 | A456CFNFSI1 | A456CFNFTI1 | ● |
Scale 2 | |||||
Range: | 0-5mm | ||||
Accuracy*: | ±1-3% or ±20μm | ||||
Resolution: | 1μm: 0-1mm; 10μm: 1-5mm | ||||
For higher resolution & accuracy on thin coatings Scale 2 gauges can be switched to the Scale 1 mode | |||||
Model B | Model S | Model T | C | ||
Elcometer 456 Ferrous Integral | A456CFBI2 | See separate gauges with N2 PINIP™ Probe | ● | ||
Scale 3 | |||||
Range: | 0-13mm | ||||
Accuracy*: | ±1-3% or ±50μm | ||||
Resolution: | 1μm: 0-2mm; 10μm: 2-13mm | ||||
Model B | Model S | Model T | C | ||
Elcometer 456 Ferrous Integral | A456CFBI3 | See separate gauges with N2 PINIP™ Probe | ● |
Gauge with Separate Probes
Model B | Model S | Model T | C | ||
Elcometer 456 Ferrous Separate | A456CFBS | A456CFSS | A456CFTS | ● | |
Elcometer 456 Non-Ferrous Separate | A456CNBS | A456CNSS | A456CNTS | ● | |
Elcometer 456 Dual FNF Separate | A456CFNFBS | A456CFNFSS | A456CFNFTS | ● | |
See separate leaflet for the Elcometer 456 Separate Probe Options |
* Whichever is the greater
● Test Certificate supplied as standard
Packing List
- Elcometer 456 Dry Film Coating Thickness Gauge
- Calibration foils (integrals only)
- Wrist harness
- Transit case (T)
- Protective case (B, S & T)
- 1 x Screen protectors (S & T)
- 2 x AA batteries
- Operating instructions
- USB cable (S & T)
- ElcoMaster® software (S & T)
Data Sheet
Standards
Elcometer 456 Coating Thickness Gauge can be used in accordance with:
• AS 2331.1.4
• AS 3894.3-B
• AS/NZS 1580.108.1
• ASTM B 499
• ASTM D 1186-B*
• ASTM D 1400*
• ASTM D 7091
• ASTM E 376
• ASTM G 12
• BS 3900-C5-6B*
• BS 3900-C5-6A*
• BS 5411-11*
• BS 5411-3*
• BS 5599
• DIN 50981*
• DIN 50984*
• ECCA T1*
• EN 13523-1
• IMO MSC.215(82)
• IMO MSC.244 (83)
• ISO 1461
• ISO 19840
• ISO 2063
• ISO 2178
• ISO 2360
• ISO 2808-6A*
• ISO 2808-6B*
• ISO 2808-7C
• ISO 2808-7D
• ISO 2808-12
• JIS K 5600-1-7
• NF T30-124
• SS 184159*
• SSPC PA 2
• US Navy PPI 63101-000
• US Navy NSI 009-32
* Standards not in bold have been superseded but are still recognised in some industries.
Accessories
Jumbo Hand Grip | |||
Ideal for precision placement for the most accurate results on flat and curved surfaces. Place the probe inside the Jumbo Hand Grip and take measurements – ideal when wearing gloves. | |||
Suitable Elcometer 456 Scale 1 or Scale 2 straight probes. | |||
Ferrous and Non-Ferrous Probes | Dual Ferrous and Non-Ferrous Probes | ||
T9997766 | |||
V-Probe Adaptor | |||
Ideal for precision placement for the most accurate results on medium and large diameter curved surfaces such as pipes and cylinders. Suitable for any Elcometer 456 Scale 1 or 2 straight probes. | |||
Ferrous and Non-Ferrous Probes | Dual Ferrous and Non-Ferrous Probes | ||
T9997381 | T99913133 | ||
Ultra / Scan Probe Replacement End Caps | |||
Highly durable – when tested on smooth surfaces probe end caps have been scanned more than 50km – each end cap snaps on to the end of the Ultra / Scan probe significantly enhancing the lifetime of the probe. | |||
Ferrous & Dual Ferrous Non-Ferrous Probes | |||
T456C23956 | Replacement Ultra / Scan Probe End Caps (3 per pack) | ||
Probe Placement Jig | |||
The Elcometer probe placement jig is the ideal accessory for measuring coatings on small or complex components when the highest levels of repeatability and accuracy are required. is supplied with a probe housing and a component holder to suit Scale 1 or Scale 2 straight probes | |||
T95012880 | Probe Placement Jig | ||
T95013028 | Component Hand Vice | ||
T95012888 | Cable Release Assembly – ideal for remote measurements | ||
T95015961 | Dual FNF Probe Housing Adaptor | ||
T95016896 | Mini Probe Housing Adaptor | ||
Calibration Foils / Coated Standards / Zero Test Plates | |||
Elcometer offers a range of individual precision foils, foil sets, coated thickness standards and zero test plates to ensure the greatest possible accuracy. | |||
Data Output Controller | |||
Enables data to be output from the Elcometer 456 via RS232 ports for the purposes of controlling automated production lines. The Elcometer Software Support Team, or users can produce their own customised software to utilise the data output from the Elcometer 456 gauge to remotely trigger pass/fail criteria for their processes. | |||
T99925387 | Elcometer Data Output Controller | ||
Operating Temp | 0 to 50°C | ||
Data Input | USB | ||
Data Output | One RS232 serial output via 9 way D-Type connector | ||
Power Supply | Requires 5V 1A (min) DC supply via mini USB. External plug-in mains adapter with interchangeable UK/EU/US/AUS pins supplied | ||
Packing List | Elcometer Data Output Controller, USB to RS232 converter lead, power supply |
T99922341 | Self Adhesive Screen Protectors (x10) | |
T99921325 | USB Cable | |
T45622371 | Benchtop Inspection Stand – for Separate Gauges |
Probes Options
All Elcometer 456 coating thickness gauge probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application.
Ferrous coating thickness gauge probes measure non-magnetic coatings on ferro-magnetic substrates. Elcometer 456 coating thickness ferrous gauges accept any ferrous probe.
Non-ferrous coating thickness gauge probes measure non-conductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe.
Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Elcometer 456 FNF coating thickness gauges accept all ferrous, non-ferrous and dual FNF probes.
Click HERE for Comprehensive Separate Probe leaflet.
Standard Straight Probes Standard probes measure coatings on both flat and curved surfaces |
|
Mini Probes Mini probes are ideal for harder to reach areas and edges |
|
Right Angle Probes Right Angle Probes are designed for taking coating thickness readings where access is restricted |
|
Plug-in Probes Plug-in probes convert a separate coating thickness gauge into an integral gauge |
|
Telescopic Probes Telescopic Probes extends right angle probes for out of reach areas |
|
Scan Probes Scan Probes allows users to take individual measurement or scan large surface areas without damaging the probes – fitted with replaceable probe caps |
|
Waterproof Probes Waterproof Probes are sealed for use underwater at depth |
|
High Temperature Probes High Temperature Probes for use on hot coated materials up to 250°C |
|
Anodising Probes Anodising Probes are chemical resistant washable probes – ideal for the anodising environment |
|
Armoured Cable Probes Armoured Cable Probes with metal reinforced heavy duty cables, reducing the risk of cable damage |
|
Soft Coating Probes Soft Coating Probes have large surface area probes for soft reach materials (HVCA approved) |
|
Specialist Probes Specialist Probes are designed for measuring coating thickness on specialist substrates such as graphite or electroplated components |
Elcometer probes have a maximum operating temperature of 80°C with the exception of separate ferrous probes 150°C and Hi-Temperature PINIP’s 250°C. The stated temperature is the substrate temperature, and the duty cycle of the probe must be reduced to ensure a minimal temperature build-up within the probe.
All Elcometer coating thickness gauge probes are supplied with a Test Certificate and a set of calibration foils appropriate to the scale range of the probe.
Elcometer 456 Dry Film Thickness Gauge Probe Options-Specifications
Scale 0.5: Range: 0-500μm |
|||||
Accuracy: | ±1-3% or ±2.5μm | ||||
Range: | 0-500μm | ||||
Resolution: |
0.1μm: 0-100μm 1μm: 100-500μm |
||||
Certificate: | • | ||||
Description Ferrous (F) |
Part Number | Minimum Headroom |
Minimum Sample Diameter |
Minimum Convex Surface Diameter |
Minimum Concave Surface Radius |
Mini Probe – Straight 45mm long | T456CFM3—A | 6mm | 3mm | 1.9mm | 6.5mm |
Mini Probe – 90° 45mm long | T456CFM3R90A | Headroom:16mm Width:7mm |
3mm | 1.9mm | 6.5mm |
Mini Probe – 45° 45mm long | T456CFM3R45A | Headroom:18mm Width:7mm |
3mm | 1.9mm | 6.5mm |
Mini Probe – Straight 150mm long | T456CFM3—C | 6mm | 3mm | 1.9mm | 6.5mm |
Mini Probe – 90° 150mm long | T456CFM3R90C | Headroom:16mm Width:7mm |
3mm | 1.9mm | 6.5mm |
Mini Probe – 90° 300mm long | T456CFM3R90D | Headroom:16mm Width:7mm |
3mm | 1.9mm | 6.5mm |
Mini Probe – 45° 300mm long | T456CFM3R45D | Headroom:18mm Width:7mm |
3mm | 1.9mm | 6.5mm |
Non-Ferrous (N) |
|||||
Mini Probe – Straight 45mm long | T456CNM3—A | 6mm | 4mm | 6mm | 8.5mm |
Mini Probe – 90° 45mm long | T456CNM3R90A | Headroom:16mm Width:7mm |
4mm | 6mm | 8.5mm |
Mini Probe – Straight 150mm long | T456CNM3—C | 6mm | 4mm | 6mm | 8.5mm |
Mini Probe – 90° 150mm long | T456CNM3R90C | Headroom:16mm Width:7mm |
4mm | 6mm | 8.5mm |
Mini Probe – 90° 400mm long | T456CNM3R90E | Headroom:16mm Width:7mm |
4mm | 6mm | 8.5mm |
Non-Ferrous – Graphite (N) |
|||||
Mini Probe – 90° Graphite 45mm long | T456CNMG3R90A | Headroom:16mm Width:7mm |
4mm | 6mm | 8.5mm |
Mini Probe – 90° Graphite 150mm long | T456CNMG3R90C | Headroom:16mm Width:7mm |
4mm | 6mm | 8.5mm |
Mini Probe – 90° Graphite 400mm long | T456CNMG3R90E | Headroom:16mm Width:7mm |
4mm | 6mm | 8.5mm |
Scale 1: Range: 0-1500μm |
|||||
Accuracy: | ±1-3% or ±2.5μm | ||||
Ranged: | 0-1500μm | ||||
Resolution: | 0.1μm: 0-100μm 1μm: 100-1500μm |
||||
Certificate: | • | ||||
Description Ferrous (F) |
Part Number | Minimum Headroom |
Minimum Sample Diameter |
Minimum Convex Surface Diameter |
Minimum Concave Surface Radius |
Straight Probe | T456CF1S | 85mm | 4mm | 4mm | 25mm |
Straight Probe, sealed | T456CF1E | 85mm | 4mm | 4mm | 25mm |
Scan Probe | T456CF1U | 86mm | 15mm | Flat Surface | |
Scan Probe, Armoured | T456CF1UARM | 140mm | 15mm | Flat Surface | |
Right Angle Probe | T456CF1R | 28mm | 4mm | 4mm | 25mm |
Mini Probe – 90°, 45mm long | T456CFM5R90A | Headroom:16mm Width:7mm |
4mm | 3mm | 6.5mm |
Mini Probe – 90°, 45mm long, sealed | T456CFME5R90A | Headroom:16mm Width:7mm |
4mm | 3mm | 6.5mm |
Mini Probe – 90°, 45mm long, 2m cable, sealed | T456CFME5R90A-2 | Headroom:16mm Width:7mm |
4mm | 3mm | 6.5mm |
PINIP™ Integral Probe | T456CF1P | 170mm | 4mm | 4mm | 60mm |
Non-Ferrous (N) |
|||||
Straight Probe | T456CN1S | 85mm | 4mm | 10mm | 10mm |
Right Angle Probe | T456CN1R | 28mm | 4mm | 10mm | 14mm |
Mini Probe – 90°, 45mm long | T456CNM5R90A | Headroom:16mm Width:7mm |
4mm | 10mm | 8.5mm |
Mini Probe – 90°, 150mm long | T456CNM5R90C | Headroom:16mm Width:7mm |
4mm | 10mm | 8.5mm |
Mini Probe – 90°, 400mm long | T456CNM5R90E | Headroom:16mm Width:7mm |
4mm | 10mm | 8.5mm |
Anodiser Probe | T456CN1AS | 100mm | 4mm | 10mm | 14mm |
PINIP™ Integral Probe | T456CN1P | 180mm | 4mm | 10mm | 50mm |
Ferrous & Non-Ferrous (FNF) |
|||||
Straight Probe | T456CFNF1S | 88mm | F: 4mm N: 6mm |
F: 4mm N: 26mm |
12.5mm |
Straight Probe, armoured cable | T456CFNF1ARM | 185mm | F: 4mm N: 6mm |
F: 4mm N: 26mm |
12.5mm |
Scan Probe | T456CFNF1U | 89mm | 15mm | Flat Surface | Flat Surface |
Right Angle Probe | T456CFNF1R | 38mm | F: 4mm N: 6mm |
F: 4mm N: 26mm |
12.5mm |
PINIP™ Integral Probe | T456CFNF1P | 180mm | F: 4mm N: 6mm |
F: 4mm N: 26mm |
65mm |
Scale 2: Range: 0-5mm |
|||||
Accuracy: | ±1-3% or ±20μm | ||||
Ranged: | 0-5mm | ||||
Resolution: | 1μm: 0-1mm 10μm: 1-5mm |
||||
Certificate: | • | ||||
Description Ferrous (F) |
Part Number | Minimum Headroom |
Minimum Sample Diameter |
Minimum Convex Surface Diameter |
Minimum Concave Surface Radius |
Straight Probe | T456CF2S | 89mm | 8mm | 4mm | 25mm |
Scan Probe | T456CF2U | 90mm | 15mm | Flat Surface | |
Right Angle Probe | T456CF2R | 32mm | 8mm | 4mm | 25mm |
Armoured Probe | T456CF2ARM | 138mm | 8mm | 4mm | 25mm |
Telescopic Probe – 56 -122cm long | T456CF2T | 36mm | 8mm | 4mm | 25mm |
Soft Coating Probe | T456CF2B | 89mm | 8mm | Flat Surface | |
Waterproof Probe, 1m cable | T456CF2SW | 138mm | 8mm | 4mm | 40mm |
Waterproof Probe, 5m cable | T456CF2SW-5 | 138mm | 8mm | 4mm | 40mm |
Waterproof Probe, 15m cable | T456CF2SW-15 | 138mm | 8mm | 4mm | 40mm |
Waterproof Probe, 30m cable | T456CF2SW-30 | 138mm | 8mm | 4mm | 40mm |
Waterproof Probe, 50m cable | T456CF2SW-50 | 138mm | 8mm | 4mm | 40mm |
Waterproof Probe, 75m cable | T456CF2SW-75 | 138mm | 8mm | 4mm | 40mm |
PINIP™ Integral Probe | T456CF2P | 174mm | 8mm | 4mm | 60mm |
Hi-Temperature PINIP™ Probe- 250°C | T456CF2PHT | 174mm | 8mm | 4mm | 60mm |
Non-Ferrous (N) |
|||||
Straight Probe | T456CN2S | 88mm | 14mm | 100mm | 150mm |
PINIP™ Integral Probe | T456CN2P | 185mm | 14mm | 100mm | 150mm |
Scale 3: Range: 0-13mm |
|||||
Accuracy: | ±1-3% or ±20μm | ||||
Ranged: | 0-5mm | ||||
Resolution: | 1μm: 0-1mm 10μm: 1-5mm |
||||
Certificate: | • | ||||
Description Ferrous (F) |
Part Number | Minimum Headroom |
Minimum Sample Diameter |
Minimum Convex Surface Diameter |
Minimum Concave Surface Radius |
Straight Probe | T456CF3S | 102mm | 14mm | 15mm | 40mm |
PINIP™ Integral Probe | T456CF3P | 184mm | 14mm | 15mm | 45mm |
Non-Ferrous (N) |
|||||
Straight Probe | T456CN3S | 170mm | 35mm | Flat Surface | |
Scale FM7: Range: 0.6-3.8mm |
|||||
Accuracy: | ±7.5% or ±114μm | ||||
Range: | 0.60-3.8mm | ||||
Resolution: | 1μm: 0-1mm 10μm: 1-3.8mm |
||||
Certificate: | • | ||||
Description Ferrous (F) |
Part Number | Minimum Headroom |
Minimum Sample Diameter |
Minimum Convex Surface Diameter |
Minimum Concave Surface Radius |
Mini Probe – 45°, 45mm long | T456CFM7R45A | 20mm | 6.5 mm | – | – |
Scale 6: Range: Ferrous: 0-25mm |
|||||
Accuracy: | ±1-3% or ±100μm | ||||
Range: | Ferrous: 0-25mm Non-Ferrous: 0-30mm |
||||
Resolution: | 10μm: 0-2mm 100μm: 2-30mm |
||||
Certificate: | • | ||||
Description Ferrous (F) |
Part Number | Minimum Headroom |
Minimum Sample Diameter |
Minimum Convex Surface Diameter |
Minimum Concave Surface Radius |
Straight Probe | T456CF6S | 150mm | 51x51mm2 | 35mm | 170mm |
Straight Probe, armoured cable | T456CF6ARM | 190mm | 51x51mm2 | 35mm | 170mm |
Scale 7: Range: 0-31mm |
|||||
Accuracy: | ±1-3% or ±100μm | ||||
Range: | 0-31mm | ||||
Resolution: | 10μm: 0-2mm 100μm: 2-31mm |
||||
Certificate: | • | ||||
Description Ferrous (F) |
Part Number | Minimum Headroom |
Minimum Sample Diameter |
Minimum Convex Surface Diameter |
Minimum Concave Surface Radius |
Straight Probe, armoured cable | T456CF7ARM | 200mm | 55x55mm2 | 40mm | 170mm |
Elcometer probes have a maximum operating temperature of 80°C with the exception of separate ferrous probes 150°C and Hi-Temperature PINIP’s 250°C. The stated temperature is the substrate temperature, and the duty cycle of the probe must be reduced to ensure a minimal temperature build-up within the probe.
All Elcometer coating thickness gauge probes are supplied with a Test Certificate and a set of calibration foils appropriate to the scale range of the probe.
Specifications
Scale 0.5: Range: 0-500μm |
|||||
Accuracy: | ±1-3% or ±2.5μm | ||||
Range: | 0-500μm | ||||
Resolution: |
0.1μm: 0-100μm 1μm: 100-500μm |
||||
Certificate: | • | ||||
Description Ferrous (F) |
Part Number | Minimum Headroom |
Minimum Sample Diameter |
Minimum Convex Surface Diameter |
Minimum Concave Surface Radius |
Mini Probe – Straight 45mm long | T456CFM3—A | 6mm | 3mm | 1.9mm | 6.5mm |
Mini Probe – 90° 45mm long | T456CFM3R90A | Headroom:16mm Width:7mm |
3mm | 1.9mm | 6.5mm |
Mini Probe – 45° 45mm long | T456CFM3R45A | Headroom:18mm Width:7mm |
3mm | 1.9mm | 6.5mm |
Mini Probe – Straight 150mm long | T456CFM3—C | 6mm | 3mm | 1.9mm | 6.5mm |
Mini Probe – 90° 150mm long | T456CFM3R90C | Headroom:16mm Width:7mm |
3mm | 1.9mm | 6.5mm |
Mini Probe – 90° 300mm long | T456CFM3R90D | Headroom:16mm Width:7mm |
3mm | 1.9mm | 6.5mm |
Mini Probe – 45° 300mm long | T456CFM3R45D | Headroom:18mm Width:7mm |
3mm | 1.9mm | 6.5mm |
Non-Ferrous (N) |
|||||
Mini Probe – Straight 45mm long | T456CNM3—A | 6mm | 4mm | 6mm | 8.5mm |
Mini Probe – 90° 45mm long | T456CNM3R90A | Headroom:16mm Width:7mm |
4mm | 6mm | 8.5mm |
Mini Probe – Straight 150mm long | T456CNM3—C | 6mm | 4mm | 6mm | 8.5mm |
Mini Probe – 90° 150mm long | T456CNM3R90C | Headroom:16mm Width:7mm |
4mm | 6mm | 8.5mm |
Mini Probe – 90° 400mm long | T456CNM3R90E | Headroom:16mm Width:7mm |
4mm | 6mm | 8.5mm |
Non-Ferrous – Graphite (N) |
|||||
Mini Probe – 90° Graphite 45mm long | T456CNMG3R90A | Headroom:16mm Width:7mm |
4mm | 6mm | 8.5mm |
Mini Probe – 90° Graphite 150mm long | T456CNMG3R90C | Headroom:16mm Width:7mm |
4mm | 6mm | 8.5mm |
Mini Probe – 90° Graphite 400mm long | T456CNMG3R90E | Headroom:16mm Width:7mm |
4mm | 6mm | 8.5mm |
Scale 1: Range: 0-1500μm |
|||||
Accuracy: | ±1-3% or ±2.5μm | ||||
Ranged: | 0-1500μm | ||||
Resolution: | 0.1μm: 0-100μm 1μm: 100-1500μm |
||||
Certificate: | • | ||||
Description Ferrous (F) |
Part Number | Minimum Headroom |
Minimum Sample Diameter |
Minimum Convex Surface Diameter |
Minimum Concave Surface Radius |
Straight Probe | T456CF1S | 85mm | 4mm | 4mm | 25mm |
Straight Probe, sealed | T456CF1E | 85mm | 4mm | 4mm | 25mm |
Scan Probe | T456CF1U | 86mm | 15mm | Flat Surface | |
Scan Probe, Armoured | T456CF1UARM | 140mm | 15mm | Flat Surface | |
Right Angle Probe | T456CF1R | 28mm | 4mm | 4mm | 25mm |
Mini Probe – 90°, 45mm long | T456CFM5R90A | Headroom:16mm Width:7mm |
4mm | 3mm | 6.5mm |
Mini Probe – 90°, 45mm long, sealed | T456CFME5R90A | Headroom:16mm Width:7mm |
4mm | 3mm | 6.5mm |
Mini Probe – 90°, 45mm long, 2m cable, sealed | T456CFME5R90A-2 | Headroom:16mm Width:7mm |
4mm | 3mm | 6.5mm |
PINIP™ Integral Probe | T456CF1P | 170mm | 4mm | 4mm | 60mm |
Non-Ferrous (N) |
|||||
Straight Probe | T456CN1S | 85mm | 4mm | 10mm | 10mm |
Right Angle Probe | T456CN1R | 28mm | 4mm | 10mm | 14mm |
Mini Probe – 90°, 45mm long | T456CNM5R90A | Headroom:16mm Width:7mm |
4mm | 10mm | 8.5mm |
Mini Probe – 90°, 150mm long | T456CNM5R90C | Headroom:16mm Width:7mm |
4mm | 10mm | 8.5mm |
Mini Probe – 90°, 400mm long | T456CNM5R90E | Headroom:16mm Width:7mm |
4mm | 10mm | 8.5mm |
Anodiser Probe | T456CN1AS | 100mm | 4mm | 10mm | 14mm |
PINIP™ Integral Probe | T456CN1P | 180mm | 4mm | 10mm | 50mm |
Ferrous & Non-Ferrous (FNF) |
|||||
Straight Probe | T456CFNF1S | 88mm | F: 4mm N: 6mm |
F: 4mm N: 26mm |
12.5mm |
Straight Probe, armoured cable | T456CFNF1ARM | 185mm | F: 4mm N: 6mm |
F: 4mm N: 26mm |
12.5mm |
Scan Probe | T456CFNF1U | 89mm | 15mm | Flat Surface | Flat Surface |
Right Angle Probe | T456CFNF1R | 38mm | F: 4mm N: 6mm |
F: 4mm N: 26mm |
12.5mm |
PINIP™ Integral Probe | T456CFNF1P | 180mm | F: 4mm N: 6mm |
F: 4mm N: 26mm |
65mm |
Scale 2: Range: 0-5mm |
|||||
Accuracy: | ±1-3% or ±20μm | ||||
Ranged: | 0-5mm | ||||
Resolution: | 1μm: 0-1mm 10μm: 1-5mm |
||||
Certificate: | • | ||||
Description Ferrous (F) |
Part Number | Minimum Headroom |
Minimum Sample Diameter |
Minimum Convex Surface Diameter |
Minimum Concave Surface Radius |
Straight Probe | T456CF2S | 89mm | 8mm | 4mm | 25mm |
Scan Probe | T456CF2U | 90mm | 15mm | Flat Surface | |
Right Angle Probe | T456CF2R | 32mm | 8mm | 4mm | 25mm |
Armoured Probe | T456CF2ARM | 138mm | 8mm | 4mm | 25mm |
Telescopic Probe – 56 -122cm long | T456CF2T | 36mm | 8mm | 4mm | 25mm |
Soft Coating Probe | T456CF2B | 89mm | 8mm | Flat Surface | |
Waterproof Probe, 1m cable | T456CF2SW | 138mm | 8mm | 4mm | 40mm |
Waterproof Probe, 5m cable | T456CF2SW-5 | 138mm | 8mm | 4mm | 40mm |
Waterproof Probe, 15m cable | T456CF2SW-15 | 138mm | 8mm | 4mm | 40mm |
Waterproof Probe, 30m cable | T456CF2SW-30 | 138mm | 8mm | 4mm | 40mm |
Waterproof Probe, 50m cable | T456CF2SW-50 | 138mm | 8mm | 4mm | 40mm |
Waterproof Probe, 75m cable | T456CF2SW-75 | 138mm | 8mm | 4mm | 40mm |
PINIP™ Integral Probe | T456CF2P | 174mm | 8mm | 4mm | 60mm |
Hi-Temperature PINIP™ Probe- 250°C | T456CF2PHT | 174mm | 8mm | 4mm | 60mm |
Non-Ferrous (N) |
|||||
Straight Probe | T456CN2S | 88mm | 14mm | 100mm | 150mm |
PINIP™ Integral Probe | T456CN2P | 185mm | 14mm | 100mm | 150mm |
Scale 3: Range: 0-13mm |
|||||
Accuracy: | ±1-3% or ±20μm | ||||
Ranged: | 0-5mm | ||||
Resolution: | 1μm: 0-1mm 10μm: 1-5mm |
||||
Certificate: | • | ||||
Description Ferrous (F) |
Part Number | Minimum Headroom |
Minimum Sample Diameter |
Minimum Convex Surface Diameter |
Minimum Concave Surface Radius |
Straight Probe | T456CF3S | 102mm | 14mm | 15mm | 40mm |
PINIP™ Integral Probe | T456CF3P | 184mm | 14mm | 15mm | 45mm |
Non-Ferrous (N) |
|||||
Straight Probe | T456CN3S | 170mm | 35mm | Flat Surface | |
Scale FM7: Range: 0.6-3.8mm |
|||||
Accuracy: | ±7.5% or ±114μm | ||||
Range: | 0.60-3.8mm | ||||
Resolution: | 1μm: 0-1mm 10μm: 1-3.8mm |
||||
Certificate: | • | ||||
Description Ferrous (F) |
Part Number | Minimum Headroom |
Minimum Sample Diameter |
Minimum Convex Surface Diameter |
Minimum Concave Surface Radius |
Mini Probe – 45°, 45mm long | T456CFM7R45A | 20mm | 6.5 mm | – | – |
Scale 6: Range: Ferrous: 0-25mm |
|||||
Accuracy: | ±1-3% or ±100μm | ||||
Range: | Ferrous: 0-25mm Non-Ferrous: 0-30mm |
||||
Resolution: | 10μm: 0-2mm 100μm: 2-30mm |
||||
Certificate: | • | ||||
Description Ferrous (F) |
Part Number | Minimum Headroom |
Minimum Sample Diameter |
Minimum Convex Surface Diameter |
Minimum Concave Surface Radius |
Straight Probe | T456CF6S | 150mm | 51x51mm2 | 35mm | 170mm |
Straight Probe, armoured cable | T456CF6ARM | 190mm | 51x51mm2 | 35mm | 170mm |
Scale 7: Range: 0-31mm |
|||||
Accuracy: | ±1-3% or ±100μm | ||||
Range: | 0-31mm | ||||
Resolution: | 10μm: 0-2mm 100μm: 2-31mm |
||||
Certificate: | • | ||||
Description Ferrous (F) |
Part Number | Minimum Headroom |
Minimum Sample Diameter |
Minimum Convex Surface Diameter |
Minimum Concave Surface Radius |
Straight Probe, armoured cable | T456CF7ARM | 200mm | 55x55mm2 | 40mm | 170mm |
Instruction Manual
Video
Faster dry film thickness test – Elcometer 456 Coating Thickness Gauge
Calibration Methods on the Elcometer 456 Coating Thickness Gauge
How to calibrate the Elcometer 456 Scan Probe